NFT 54-018
uPVC Telecommunication Pipes
Specialized ducting for telecommunication lines and fiber optic installations.
Request a quote
- Size range
- 50 – 200 mm
- Usage
- Manufactured in accordance with NFT 54-018 standards, with diameters of 50mm and 100mm. Cable ducts for direct burial range from 50mm up to 200mm.
- Socket type
- Solvent Cement (S.C.) socket
- Colors
- Grey
- Lengths
- 6-meter lengths
Technical specifications
NFT 54-018
| OD (mm) | Wall Thickness S (mm) | Socket Type |
|---|---|---|
| 50 | 2 | S.C. |
| 100 | 2 | S.C. |
Dimensions are in mm
Cable Ducts
| OD (mm) | MB (SN4) | DB (SN8) | Socket Type |
|---|---|---|---|
| 50 | 3 | 1.8 | S.C. |
| 75 | 3.5 | 2.3 | S.C. |
| 100 | 2.5 | 3 | S.C. |
| 110 | 3 | 3.2 | S.C. |
| 160 | 4 | 4.7 | S.C. |
| 200 | 4.9 | 5.9 | S.C. |
Dimensions are in mm
For non-standard lengths, thicknesses, and colors — contact Moli IPI.
Jointing procedure
Four steps, in order.
- Step 01
Clean surfaces
Clean pipe and fitting ends from dust and any burrs to ensure a clean surface for bonding.
- Step 02
Mark insertion point
Insert the pipe or fitting into the joint and mark with a line the point of farthest travel.
- Step 03
Apply solvent cement
Apply solvent cement to both ends.
- Step 04
Join and set
Re-insert pipe or fitting ensuring the marked line coincides with the edge of the pipe and leave to dry.
Next line
View Pressure PipesuPVC Pressure Pipes